Lesson 3 of 3 · Carry the reference uncertainty
Carry the reference uncertainty
26 minute lesson · 3 checks along the way
Your goal for this lessonCarry independent, common and structured uncertainty through selected observations and shared-reference contrasts without treating correlated information as independent.
In this lesson 5 sections · 3 checks
Read & understand
A preliminary comparison needs an uncertainty budget
The Philippine work includes training in processing GEMS and Pandora data, followed by a preliminary comparison described in PhilSA’s 2025 report. The report lists installations in Metro Manila, Ilocos Norte, Palawan and Cebu and describes the Quezon City/GEMS comparison as preliminary. These are reporting-year statements, not a check of current uptime. That account motivates further monitoring; it does not provide a national accuracy score. A useful comparison needs more than a pair of plotted values. It must specify the product, the selected observations, their sampling compatibility and the uncertainty of the quantity being compared. A visually close match cannot supply those missing definitions.
The PGN documentation distinguishes independent, common and structured uncertainty contributions. These describe different ways an error can be shared among observations. Our numerical components are fictional: I = 3, C = 4 and S = 2 micromol/m². They are not measured performance of the Philippine instruments and are not estimated from the scatter of the nine example columns. Reported uncertainty also need not include every algorithm, cross-section or representativeness effect. A quality flag can identify a problem without quantifying every possible contribution to a numerical budget.
Read & understand
Assign each component its shared cause
Write the error of observation i as eᵢ = aᵢ + c + b_g(i). Each aᵢ is independent across readings with standard uncertainty I. The same c affects all observations using our stipulated reference R1, with standard uncertainty C. Each group A, B or C has its own shared b_g with standard uncertainty S. The three group errors are independent of one another. All these components are mutually independent and have zero mean in this model. These are declared error-sharing assumptions, not conclusions inferred from similar-looking values.
A single reading therefore has variance I²+C²+S² = 9+16+4 = 29 in squared micromol/m² units, and standard uncertainty √29 ≈ 5.385 micromol/m². Standard uncertainties add in quadrature here because the components are independent; variances and standard uncertainties are different quantities. Our target for averaging is the mean of the selected true columns. Those true columns need not all be identical. Variation in the reported columns can reflect real variation as well as measurement error, so their spread cannot simply replace the supplied component budget.
Read & understand
Average blocks without losing their shared errors
For n equally weighted readings, the independent contribution to the mean’s variance is I²/n. The common contribution remains C²: averaging c nine times still gives c. Two useful structured-error assumptions illustrate the remaining choice. If one structured error is shared by every reading, its contribution remains S², giving 9/9+16+4 = 21 for nine readings. If instead structured errors are independent across readings, the result is (9+4)/9+16 = 157/9 ≈ 17.444. Calling an interval short or long does not by itself establish which covariance assumption is valid.
Our model sits between these particular cases because it has three independent structured groups, each shared within three readings. Group g has weight m_g/n in the mean, so its structured variance contribution is S²(m_g/n)². Summing the independent groups gives S² Σ_g(m_g/n)². With three equal groups, this is 4 × 3 × (1/3)² = 4/3. The complete variance is 9/9+16+4/3 = 55/3 ≈ 18.333. Its square root is about 4.282 micromol/m² for the reported mean of 22.
The covariance matrix makes the same sharing explicit. Its diagonal entries are 29. Two different readings in one group share c and b_g, giving covariance 16+4 = 20. Readings in different groups share only c, giving covariance 16. For weights wᵢ = 1/9, the mean’s variance is ΣᵢΣⱼ wᵢwⱼKᵢⱼ. Include both ordered off-diagonal terms. Ignoring them would treat shared information as independent. The two earlier structured-error cases are declared alternatives, not universal bounds for every possible correlation model.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Change the selection or reference and recalculate
The geometry lesson’s h = 2 km selection retains six readings in two equal groups. Its mean is 21.5 and its variance is 9/6+16+4/2 = 19.5, giving standard uncertainty about 4.416 micromol/m². Reusing the nine-reading uncertainty would describe the wrong selection. Adding readings also has different effects depending on their sharing: eighteen readings in the same three equal groups give 9/18+16+4/3 = 107/6, while eighteen spread across six independent equal groups give 9/18+16+4/6 = 103/6. Both retain the common term.
Equal group weights cannot be assumed when group sizes differ. With sizes 6, 2 and 1, the structured contribution is 4[(6/9)²+(2/9)²+(1/9)²] = 164/81. Adding the independent and common contributions gives 1541/81, about 19.025. The large group carries more of one shared error into the mean. If structured errors are correlated across groups, additional covariance terms are required; neither group count nor total sample count alone determines the answer.
Now compare group means rather than an absolute overall mean. A, B and C have means 21, 22 and 23, so C−A is 2 micromol/m². Each three-reading group mean has variance 9/3+16+4 = 23. Under the same additive reference error with equal sensitivity, covariance between the two means is 16. The difference variance is 23+23−2×16 = 14, with standard uncertainty √14 ≈ 3.742. If independent reference errors of the same size are stipulated instead, that covariance is zero and the variance becomes 46, with standard uncertainty about 6.782. Different reference labels alone do not prove independence. Unequal sensitivities to one shared reference would leave a residual instead of exact cancellation.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Write a comparison that another analyst can reconstruct
A reproducible result names the product and processor interpretation, accepted IDs, geometry assumptions, units, target mean or contrast, and component-sharing model. For the baseline case, report the nine-ID mean of 22 micromol/m² with standard uncertainty about 4.282 under the stipulated three-block model. For the height-changed case, report six IDs, mean 21.5 and standard uncertainty about 4.416. Do not collapse these into one result whose selection rule is unstated.
These standard uncertainties do not establish a confidence-interval coverage probability. Finite variances alone do not supply a Gaussian distribution, a significance threshold or a national performance claim. A same-reference contrast can have less measurement uncertainty because a shared component cancels, while spatial and temporal representativeness remain unresolved. The observed two-unit contrast is therefore not automatically evidence of a physical pollution change. The value of the calculation is that its assumptions and limitations are visible enough for another analyst to challenge, reproduce or revise.
Carry shared errors through a mean and contrast
Original fictional error model with mutually independent, zero-mean latent components of finite variance. The common reference is shared equally by all nine readings; structured errors are shared only within each group. No distribution or confidence coverage is assumed.
Open full-size diagram in a new tab: Carry shared errors through a mean and contrastRead diagram data as a table
| Quantity | Variance ((µmol/m²)²) |
|---|---|
| Independent contribution | 1 |
| Common contribution | 16 |
| Structured contribution | 4/3 |
| Mean total | 55/3 |
| Single group mean | 23 |
| C-minus-A with shared reference | 14 |
| C-minus-A with independent references | 46 |
Standard uncertainty of the nine-reading mean: √(55/3) ≈ 4.282 µmol/m². Three equal groups with independent structured errors and one equally shared additive reference error are stipulated.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: PhilSA: GEMS and Pandora processing workshopTraining took place 5–6 December 2024. The report does not establish cessation of instrument operations.
- Read: PhilSA Annual Report 2025, printed page 68PDF page 89 reports four installation localities and a preliminary Quezon City/GEMS comparison, without a national accuracy or uptime result.
- Read: PGN readme: uncertainty and quality flagsSections 5.2, 5.4 and 5.5 support component sharing, the nine-code matrix and omitted effects. Section 5.3’s rnvs4 summary is not silently equated with detailed rnvs3.
- Read: PGN readme: product identity and statusRead the complete retrieval/processor identity and product status. Official status alone is not this course’s acceptance decision.