Lesson 1 of 3 · Qualify the ground reference
Qualify the ground reference
26 minute lesson · 3 checks along the way
Your goal for this lessonQualify a versioned Pandora ground-reference product by physical quantity, retrieval setup, processor, uncertainty metadata and the two parts of its data-quality flag.
In this lesson 5 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
A partnership hands over more than an instrument
PAPGAPI-PAN Philippines connects ground observations, satellite data and the people who interpret them. PhilSA leads the Philippine implementation, working through international cooperation and local operating institutions. The Pandora instruments are ground-based spectrometers. GEMS is an atmospheric instrument aboard GEO-KOMPSAT-2B, also called Cheollian 2B. These are complementary parts of a comparison, not different names for one spacecraft. A station can supply useful reference information only when another analyst can identify what its reported numbers mean.
The dated accounts describe different milestones. PhilSA and KOICA signed their agreement on 2 August 2023. The later turnover account identifies 19 July 2024 as the first Manila Observatory installation and 12 August as the ceremonial turnover. An earlier expectation of installation during 2023 is not evidence that installation actually happened then. Likewise, an undated overview describing two planned units cannot establish a current installed count. Keep the date and kind of each claim attached to it: agreement, installation, handover and demonstrated data performance answer different questions. Local operation and PhilSA’s interpretation and integration of data create a practical need for a common measurement contract.
Participants view the Pandora control equipment in the Manila Observatory control room during the August 2024 turnover activities. Hardware operation, retrieval processing and data-quality review are separate parts of the reference-data chain.
Look closely
Which product checks can this hardware photograph establish?
See what to notice
It documents equipment and the event. Product quantity, processor, quality flag and uncertainty must come from versioned data and records.
Read & understand
Name the quantity before reading the number
Imagine preparing a ground reference for a hypothetical comparison of total nitrogen-dioxide columns. A column reports an amount integrated through a vertical extent, per unit area. A total column, a tropospheric column and a surface number density describe different quantities. TotCol and TropCol can both use mol/m² while covering different vertical extents. SurfDens uses a volume unit, such as mol/m³. Equal-looking numbers, or even equal units, therefore do not establish equal physical meaning. A surface density cannot be substituted for a total column by moving a decimal point.
Our fictional target specifies NO2 TotCol, direct-sun observations, retrieval setup rnvs3, processor 1.8, official product status and known component uncertainties. The combined retrieval-version label is rnvs3p1-8. The detailed rnvs3 page allows processor 1.8 and higher; restricting this example to 1.8 is our study rule, not a claim that 1.9 is an invalid processor for rnvs3. The preserved readme’s own version, 1.8.11, identifies a document rather than a processor. These labels must not be interchanged. This exercise uses the documented historical interpretation; it does not identify the processor currently operating at a Philippine station. The documentation also contains a summary-table rnvs4 label alongside the detailed rnvs3 taxonomy. We retain that discrepancy rather than silently declaring the codes equivalent.
For a compatible total column, unit conversion is straightforward: one mol contains one million micromol, so 2.2 × 10⁻⁵ mol/m² becomes 22 micromol/m². The area unit remains unchanged. Conversion changes the numerical scale and the uncertainty scale together; an uncertainty of 3 × 10⁻⁶ mol/m² becomes 3 micromol/m². It changes neither the sampled atmosphere nor the retrieval method. Preserve the original units and record the conversion so another analyst can reconstruct the displayed values.
Read & understand
Read both parts of the quality flag
The quality flag carries two separately encoded judgments. Its unit digit expresses nominal quality; its decade carries quality-assurance or unusability information. Treating the flag as a single ranking, or inspecting only its last digit, loses that distinction. In the reviewed convention, DQ0 is high quality with quality assurance complete. DQ10 still has nominal high quality, but formal quality assurance is incomplete. DQ20 is unusable even though its last digit is also zero. A zero at the end of a code is not permission to use the observation.
The complete grid has nine codes. DQ0, DQ1 and DQ2 have completed quality assurance and respectively high, medium and low nominal quality. DQ10, DQ11 and DQ12 carry the same nominal-quality categories while quality assurance remains incomplete. DQ20, DQ21 and DQ22 are unusable regardless of their unit digit. These are two encoded attributes, not a claim that the attributes are statistically independent. In particular, DQ11 does not become acceptable merely because its nominal category could suit some applications: its assurance status must also meet the chosen policy.
Our declared target requires the complete flag to equal zero. This is a high-quality-only analysis rule, not a claim that every other flag has the same meaning. DQ1 can be relevant to an application that deliberately accepts its lower quality category; it does not satisfy this target. If a DQ10 observation later receives DQ1 after review, completing quality assurance has not made it pass the high-only rule. The nominal quality and assurance status must both be reconsidered. Nor does DQ0 guarantee that the reference samples the same air as a satellite observation or includes every possible error source.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Apply a declared qualification rule
The teaching packet contains fifteen invented rows, not Philippine measurements or a native PGN output file. Nine rows, A1 through C3, meet the product, mode, processor, status, unit, complete-flag and uncertainty requirements. Their displayed columns are A: 18, 21, 24; B: 19, 22, 25; and C: 20, 23, 26 micromol/m². Retain their IDs with their values. Their sum is 198, so their arithmetic mean is 198/9 = 22 micromol/m². This is useful bookkeeping, but spatial compatibility and uncertainty have not yet been established.
The other six rows fail for different reasons. Q10 awaits quality assurance; Q20 is unusable. SURF describes a surface-density/profile product, while TROP covers a different vertical extent and observation mode. Their copied uncertainty fields do not make either compatible with the target. P19 uses processor 1.9, outside this explicitly version-specific analysis. MISSING lacks the common-uncertainty field. Hold or exclude each with its reason; never replace a rejected value or a missing uncertainty with zero. In particular, MISSING and P19 both display 22, the retained mean. A plausible value does not repair incompatible or incomplete metadata.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Freeze the interpretation and carry its limits forward
A qualification record should preserve the target, source-document versions, selected IDs, exclusions, units and missing fields. It should also distinguish the observation’s product status from the study’s acceptance decision. All fifteen rows stipulate official status; that alone does not make them pass the remaining checks. If an analyst later chooses processor 1.9, that can define a different valid study with its own compatible metadata. It does not justify silently adding P19 to the present calculation. If the missing common uncertainty is recovered, re-evaluate MISSING rather than pretending that the old incomplete record was adequate.
The result of this lesson is nine eligible records, not a certified air-quality conclusion. We have checked what the numbers claim to represent and how they were processed. We have not yet checked where the direct-sun path sampled the atmosphere, whether the satellite comparison represents the same volume and time, or how the observations share uncertainty. The next lesson carries these exact nine IDs into a directional sampling-location model. Keeping the selection trail intact lets us explain why a later mean changes without mistaking a change in the selected observations for a change in the atmosphere.
Qualify a versioned ground reference
The quality categories come from PGN documentation; the product contract and high-only acceptance rule are fictional teaching choices. DQ0 passes only the flag rule. Quantity, retrieval setup, processor, units and uncertainty fields must also qualify.
Open full-size diagram in a new tab: Qualify a versioned ground referenceRead diagram data as a table
| Status | High nominal quality | Medium nominal quality | Low nominal quality |
|---|---|---|---|
| QA complete | DQ0 | DQ1 | DQ2 |
| QA incomplete | DQ10 | DQ11 | DQ12 |
| Unusable | DQ20 | DQ21 | DQ22 |
Only DQ0 passes the declared high-only flag policy; all other product and metadata checks still apply.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: PhilSA and KOICA: the August 2023 agreementAgreement signed 2 August; the 4 August account describes planned installation, not proof of completion.
- Read: PhilSA: PAPGAPI-PAN overviewUndated partnership and two-unit plan. Later dated reports must be considered separately.
- Read: PhilSA: Pandora turnover and local operatorsDistinguishes the 19 July installation from the 12 August 2024 ceremony; supplies the photograph context.
- Read: PGN readme: document versionsThe preserved document identifies version 1.8.11; this is distinct from a processor version and is not evidence of a Philippine deployment.
- Read: PGN readme: product identity and statusRead the complete retrieval/processor identity and product status. Official status alone is not this course’s acceptance decision.
- Read: PGN readme: retrieval setupsSection 2.10 defines rnvs3 as direct-sun NO2 total column with BL+NO2s and processor 1.8 or higher. The single-height model and 1.8-only study rule are fictional simplifications.
- Read: PGN readme: uncertainty and quality flagsSections 5.2, 5.4 and 5.5 support component sharing, the nine-code matrix and omitted effects. Section 5.3’s rnvs4 summary is not silently equated with detailed rnvs3.