Lesson 2 of 3 · Bandwidth and component inference
Use bandwidth to question a reading
20 minute lesson · 3 checks along the way
Your goal for this lessonInfer an isolated-tone contribution and flat spectral density from two matched ideal bandwidth measurements; identify violations that invalidate the inference.
In this lesson 4 sections · 3 checks
Read & understand
A bandwidth change can change the reading
A spectrum measurement selects a frequency range. A narrow tone and a broad background need not respond the same way when that range changes. The first lesson held the measured band fixed; this lesson changes it deliberately. We will use two matched observations to ask how much of their difference can be explained by a flat background. The model is a teaching experiment motivated by radio measurement, not a description of SIKLAB’s receiver or an instruction for configuring flight hardware.
Assume an isolated tone has fixed power T and lies wholly inside both ideal rectangular filters. A stationary, flat continuum has power density D in milliwatts per hertz. Both observations refer to the same calibrated input point, with unchanged gain and a linear receiver. For a filter of width B hertz, total admitted power is P(B) = T + D B. This is an expected-power model in which the contributions add. The continuum may include background or receiver noise referred to that point; this equation alone cannot tell which.
Read & understand
Recover two unknowns from two matched observations
For an original example, a 1,000 Hz bandwidth gives 0.0000004 mW, while a 4,000 Hz bandwidth gives 0.0000007 mW. Subtracting the measurements cancels the same admitted tone. The remaining 0.0000003 mW is spread across the additional 3,000 Hz, so D = (0.0000007 − 0.0000004)/(4,000 − 1,000) = 0.0000000001 mW/Hz. Multiplying density by bandwidth returns a power; a density value cannot be added directly to a power.
Use either observation to recover T. At 1,000 Hz, the continuum contributes 0.0000001 mW, leaving T = 0.0000003 mW. At 4,000 Hz, it contributes 0.0000004 mW, leaving the same tone power. Reconstructing both original measurements checks the arithmetic. It does not independently verify the assumptions, because two adjustable quantities can fit two observations exactly. A third matched bandwidth can test a prediction, while still requiring checks that the signal and instrument remained comparable.
One tone, two bandwidths
Original ideal rectangular-filter model with the same fully admitted tone, flat stationary continuum and calibrated reference point. Bars share a linear scale.
Open full-size diagram in a new tab: One tone, two bandwidthsRead diagram data as a table
| Bandwidth (Hz) | Tone (mW) | Continuum (mW) | Total (mW) |
|---|---|---|---|
| 1000 | 0.0000003 | 0.0000001 | 0.0000004 |
| 4000 | 0.0000003 | 0.0000004 | 0.0000007 |
| Difference | 0 | 0.0000003 | 0.0000003 |
Original ideal rectangular-filter model with the same fully admitted tone, flat stationary continuum and calibrated reference point. Bars share a linear scale.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Different components scale differently
With only the flat continuum present, increasing bandwidth from 1,000 to 4,000 Hz multiplies admitted power by four, a level increase of about 6.0206 dB. With only the fully admitted isolated tone present, its integrated power stays fixed. In the mixed example, total power rises by a factor of 0.7/0.4 = 1.75, or about 2.4304 dB. Treating every observed component as if its power must quadruple would erase the distinction the model is intended to investigate.
Real instruments have filter shapes, calibration factors and effective noise bandwidths. A nominal resolution-bandwidth setting is not automatically the exact rectangular B used here. A displayed peak is also not necessarily integrated power over a whole band. Our model starts with calibrated band powers and known ideal widths; it does not tell a learner to add screen pixels or substitute an arbitrary menu setting into the equation. The documented instrument method determines how a real band-power result is formed.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Try to break the explanation
Suppose a wider filter admits a second tone that the narrow filter excludes. The observed difference now includes that tone as well as continuum power; solving the two equations would wrongly assign all of it to a flat density. A source that changes strength between observations creates a similar ambiguity. A drifting gain, non-flat background or clipped receiver also violates the setup. A plausible numerical answer cannot repair an experiment that changed several relevant conditions at once.
A defensible follow-up holds the configuration and source conditions stable, repeats matched observations, checks a third bandwidth and preserves the actual filter and calibration information. If the inferred T or D is negative under a model requiring nonnegative components, investigate uncertainty and model mismatch. Do not silently replace it with a claim of no signal. The goal is to find out whether the measurements support this explanation, not to force every dataset into it.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.