Lesson 1 of 3 · Power and logarithmic averages
Choose the quantity before averaging
18 minute lesson · 3 checks along the way
Your goal for this lessonConvert dBm to linear power, distinguish logarithmic and physical means, and apply duration weights with a stated reconstruction assumption.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
A planned measurement needs a defined quantity
SIKLAB is PhilSA’s launch-capability training project with Perigee Aerospace. PhilSA’s September 2026 account describes a planned radio-signal payload for a Philippine sounding-rocket demonstration. Its November update reports that engineers completed training in October, with the demonstration targeted for early 2027. These are different milestones: training completion is established by the report; a completed Philippine payload flight is not. The measurements in this course are original classroom examples, not SIKLAB results or specifications.
A radio instrument can return a series of changing power readings. Before asking for their average, decide what quantity the answer should describe. Mean physical power describes energy received per unit time. A mean logarithmic level summarizes levels on a logarithmic scale. Neither phrase is interchangeable with peak power, a decoded message, or a map of usable cellular service. Preserve the frequency range, acquisition times, instrument configuration and reference point alongside the readings. A number without that context can answer the wrong question very precisely.
SIKLAB engineers complete rocket training in South Korea: PhilSA engineers and officials at the rocket-training completion ceremony in Okcheon on October 20,2026. This photograph documents the training milestone, not a completed Philippine demonstration launch or measured radio performance.
Look closely
Does this training-completion photograph establish the payload’s measured radio performance?
See what to notice
It documents the training milestone. The classroom readings are fictional, and the source describes a Philippine demonstration still planned for early 2027.
Read & understand
Convert before averaging physical power
The level L in dBm represents power P relative to one milliwatt: L = 10 log10(P / 1 mW). Conversely, P = 10^(L/10) mW. A ten-decibel increase multiplies power by ten; a negative dBm level still represents positive power below one milliwatt. Our exercise assumes calibrated, noiseless power values measured at the same reference point and over the same frequency band. We are not comparing amplitudes, so the conversion uses ten times the logarithm of a power ratio.
Imagine two readings, −60 dBm and −40 dBm, each representing an equal time interval with constant power. Their linear powers are 0.000001 mW and 0.0001 mW. Averaging those powers gives 0.0000505 mW. Converting that result back gives approximately −42.9671 dBm. Averaging the displayed levels directly instead gives (−60 − 40)/2 = −50 dBm, corresponding to 0.00001 mW. That is the geometric mean of these two positive powers, not their arithmetic mean. The stronger interval contributes much more energy than the weaker one.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Time weights belong to the observation
Now suppose the −60 dBm condition lasts nine seconds and the −40 dBm condition lasts one second. The time-average power is [9 × 0.000001 + 1 × 0.0001]/10 = 0.0000109 mW, or about −49.6257 dBm. Giving the two records equal weight would describe equal durations that did not occur. The calculation assumes each stated level holds throughout its interval; two isolated snapshots alone would not establish what happened between them.
Split the nine-second interval into nine one-second records with the same level. The result must stay unchanged: the physical history is identical. This is a useful check on an averaging method. Likewise, adding the same ten-decibel gain to every level multiplies every linear power by ten, so the final physical-power mean also rises by ten decibels. If all levels are equal, logarithmic and physical averaging agree. Their difference appears when levels vary, and the observation weights determine how much each interval contributes.
Two means, different quantities
Original calibrated, noiseless, constant-interval model; all measurements share a band and reference point. No SIKLAB performance is represented.
Open full-size diagram in a new tab: Two means, different quantitiesRead diagram data as a table
| Summary | Durations (seconds) | Result |
|---|---|---|
| Mean physical power | 1 and 1 | 0.0000505 mW; −42.9671 dBm |
| Mean logarithmic level | 1 and 1 | −50 dBm |
| Time-average physical power | 9 and 1 | 0.0000109 mW; −49.6257 dBm |
Original calibrated, noiseless, constant-interval model; all measurements share a band and reference point. No SIKLAB performance is represented.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Name the summary and its limits
Instrument documentation distinguishes several detector and averaging modes. A peak detector, a power average and a logarithmic average can legitimately produce different numbers from the same changing signal. Record the selected operation and choose it for the investigation’s question. An average of logarithmic levels is not inherently an error; calling it time-average physical power without the required transformation would be an error. In a report, show the units, weights and conversion so another person can reproduce the result.
Even a correctly computed time average describes only the recorded band, reference point and interval. A changing antenna direction, position, receiver setting or source activity could influence it. A brief flight path cannot establish nationwide coverage, and received power alone does not establish message delivery. For SIKLAB’s proposed demonstration, the useful habit is to preserve enough measurement context to support the stated objective. The fictional arithmetic here neither predicts its payload’s readings nor certifies an eventual service.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: PhilSA: rocket training and planned radio-signal payloadProject partnership and the stated purpose of the planned payload. Plans are not flight results; no receiver configuration inferred.
- Read: PhilSA: engineers complete rocket training4November2026report,20Octobercompletion ceremony, early2027demonstration target. Training completion does not establish Philippine launch completion.
- Read: Keysight: spectrum analyzer detectors, averaging and band powerReviewed detector and averaging sections, resolution-bandwidth explanation and band markers. General instrument documentation; not SIKLAB hardware. The inverse rectangular-filter model is independently constructed, not a vendor performance claim.