Lesson 3 of 3 · Delivered power, interface loss and bounded evidence
Test power across a docked interface
14 minute lesson · 3 checks along the way
Your goal for this lessonBalance source, interface and load energy in a stated circuit and distinguish a successful bounded power-transfer test from a universal service claim.
In this lesson 4 sections · 3 checks
Read & understand
Electrical transfer supplies evidence beyond mechanical docking
ISRO reported a second SpaDeX docking on April 20, 2025, followed by power-transfer tests on April 21. A heater on one spacecraft was powered from the other, and the direction was reversed. The report describes approximately four minutes of power transfer. This is evidence about the tested interface, load and interval. It is not a claim that every resource could pass through the connection, that transfer could continue indefinitely or that the same behavior would hold for an arbitrary load.
Mechanical docking establishes a connection with its own requirements. Electrical transfer additionally needs a circuit, compatible interfaces and evidence that energy reached the intended recipient. The source, conducting interface, load and measurement points must be identified separately. The following original circuit is deliberately simpler than a spacecraft power system. Its values and test duration are fictional; they are not a reconstruction of the flight experiment or an instruction for operating spacecraft equipment.
Read & understand
Distinguish source voltage from voltage at the load
Assume an ideal source maintains exactly 24 volts across a series circuit. The complete round-trip interface resistance is one ohm, including both outgoing and return paths. A heater has a fixed resistance of eleven ohms. There are no converters, batteries or additional loads, and both resistances remain constant. The total resistance is twelve ohms, so Ohm’s law gives a current of 24/12 = 2 amperes through both elements.
The heater receives a voltage of IR = 2 × 11 = 22 volts. The remaining two volts appear across the interface resistance. Heater power is I²R = 4 × 11 = 44 watts. Interface loss is 4 × 1 = 4 watts, while source power is VI = 24 × 2 = 48 watts. The power balance closes: 48 = 44 + 4. Using 24 volts directly across the eleven-ohm heater would ignore the series voltage drop and describe a different circuit.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Integrate power over the stated test interval
Hold this invented circuit steady for 180 seconds. Multiplying power by time gives heater energy of 44 × 180 = 7,920 joules, interface dissipation of 720 joules and total source energy of 8,640 joules. Delivered energy plus interface loss equals supplied energy. These are energy quantities; watts describe the rate of transfer. Converting seconds to hours would change the energy unit to watt-hours, not leave the same numerical answer in joules.
Within this model, the fraction of source power delivered to the heater is 44/48 = 11/12, about 91.7 percent. That ratio concerns only the specified two-resistor path. It excludes battery charging efficiency, converter losses, control electronics and temperature-dependent behavior. The source voltage is held constant by assumption. A regulated or current-limited spacecraft supply can respond differently when a contact resistance or load changes, so this formula is not a general performance prediction for the actual SpaDeX interface.
A connected circuit still has an interface loss
Original constant-source-voltage series circuit. The lumped interface resistor represents the total outgoing and return-path resistance; all other drawn wire is ideal. The example separates source energy, delivered energy and interface dissipation.
Open full-size diagram in a new tab: A connected circuit still has an interface lossCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Make the test distinguish competing explanations
A useful experimental record links source voltage and current to measurements at the receiving load, with synchronized time and known switching states. An on/off comparison can help distinguish commanded heater operation from background warming, provided competing conditions are controlled. A rising temperature alone does not directly measure electrical energy: heat capacity, thermal losses and other heat sources matter. Likewise, source current alone does not prove that every joule reached the intended heater.
Reversing the transfer direction provides an additional test of the opposite source-and-receiver path. It does not establish identical losses in both directions unless the relevant measurements support that conclusion. Keep the measured duration, direction, load, interface configuration and limits with the result. SpaDeX’s bounded flight demonstrations are valuable precisely because they supply concrete evidence. Extending that evidence to another spacecraft or a longer operation requires a stated engineering argument and appropriate further tests, rather than assuming that successful docking proves every service through the joint.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: SPADEX Mission: Successful demonstration of Second Docking and Power TransferApril 2025 achieved second docking and bidirectional heater-transfer experiment. Approximately four minutes is bounded evidence, not unlimited power service.
- Read: PSLV-C60 / SPADEX Mission brochurePrelaunch spacecraft, docking-mechanism and power-connector context. The course masses, spring, circuit and tolerances are independent fictional examples.
- Read: SPADEX Satellites Re-entry into Earth’s Atmosphere on October 12, 2026October 23, 2026 final report: both spacecraft reentered October 12 after fuel exhaustion and orbital decay. This is not described as controlled deorbit.