Lesson 2 of 3 · Timestamp calibration and shared errors
Calibrate recorded time markers
22 minute lesson · 3 checks along the way
Your goal for this lessonRecover a delay from paired recordings, bound sample-grid error and account for a timing error shared by multiple measurements.
In this lesson 4 sections · 3 checks
Read & understand
Define what each recording measures
SPATIUM-II was a payload section aboard KITSUNE, not a separate satellite flying beside it. The team used ground-origin radio sequences and onboard processing. Its development report describes synchronized timing markers and a local ground recording alongside the satellite recording. Comparing the position of a known sequence with a marker provides a timestamp inside a recorded waveform; it does not make the receiver and synchronization delays disappear.
For an original model, identify the same transmitted code feature in both recordings and use the same reference epoch. In recording i, define qᵢ=(code sample−marker sample)/Fₛ. Each code feature must be matched to the correct repetition; assume that matching is already established. Let B be the calibrated difference of the two effective code-to-marker instrument delays, with ideal synchronization for now. Our measurement equation is qₛ−qɢ=propagation time+B. Thus propagation time is qₛ−qɢ−B. The sign convention is part of the calibration, not something to choose after seeing an answer.
Read & understand
Subtract the unequal instrument contribution
At Fₛ=1,000,000 samples per second, the ground marker and code feature occur at samples 1,000 and 1,400. The satellite marker and code feature occur at 2,000 and 2,605. These yield qɢ=400 microseconds and qₛ=605 microseconds. Their difference is 205 microseconds. An independently measured B=+3 microseconds leaves 202 microseconds of propagation time. Subtracting the raw code indices alone would mix the unrelated origins of the two recording buffers.
Adding any constant buffer-origin offset to both indices within one recording leaves q unchanged. A physical marker error is different: if the satellite marker occurs one microsecond late relative to the assumed common epoch, its code-minus-marker value falls by one microsecond. That timing-reference error does not cancel against an independent ground marker. A stable oscillator, correct sample rate and calibrated receiver still need a reliable relationship between the two epochs.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep resolution separate from a total error bound
Assume nearest-sample timestamps and an exact sample rate. Each of the four timestamp errors is bounded by half a sample, or 0.5 microseconds here. The worst-case bound on their signed combination is therefore two microseconds. If the calibration B also has a bounded ±0.3-microsecond error, the propagation estimate has a ±2.3-microsecond bound under these assumptions. Multiplying by c=299,792,458 m/s gives a one-way range-equivalent bound of about 690 metres; there is no factor of one-half for this one-way measurement.
This bound omits any additional synchronization, rate, geometry or detection error. Independence is not needed for the worst-case sum, and a bound is not a standard deviation. A finer grid reduces this particular quantization contribution, but does not remove an unknown clock offset. The 2025 SPATIUM-II paper’s abstract reports errors of approximately ±50 km for its configured system. That historical result is not a confidence interval specified here, and it must not be replaced by a sampling-grid estimate.
Calibrate each timing contribution
Original timestamp and bounded-error example. The shared-marker identity concerns two features using one marker; it does not synchronize two independent receivers.
Open full-size diagram in a new tab: Calibrate each timing contributionCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Recognize an error shared by two differences
Suppose two code features in one recording use the same measured marker: a=C₁−P and b=C₂−P. Let independent code-time errors each have standard deviation 1 microsecond, while the shared marker error has standard deviation 3 microseconds. Each difference has variance 1²+3²=10 square microseconds. Their covariance is 9 because the same marker error enters both with the same sign. The variance of a−b is 10+10−2×9=2, so its standard deviation is √2 microseconds.
Treating a and b as independent would instead give √20 microseconds. The cancellation is visible directly in a−b=C₁−C₂; it applies to the separation of those two features, not to either feature’s absolute timestamp. Different receivers normally do not share the same measured marker error. Draw the actual error dependencies before combining uncertainties. A successful timing demonstration needs a defined estimator and calibrated chain, followed by evidence that its remaining errors permit the scientific question.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Kyutech/MEXT: onboard radio-ranging development reportRelevant pages 6–22, including the marker method and delay budget on pages 19–20. The report documents development tests; the numerical timing/error model here is original.
- Read: SPATIUM-II: January 2023 team presentationSlides 14–26 show recordings, onboard sequence detection and the limitations reported at that time.
- Read: Kishimoto and colleagues: 2025 on-orbit resultsAbstract and highlights only were accessible: operation interval and approximate ±50 km result. The full paper’s uncertainty analysis was not reviewed.