Lesson 1 of 3 · Clock stability and independent references
Measure stability without claiming accuracy
20 minute lesson · 3 checks along the way
Your goal for this lessonCalculate a stated frequency-stability estimate and explain what constant bias, averaging time and the reference leave unresolved.
In this lesson 4 sections · 3 checks
Read & understand
Start with a clock and a separate reference
SPATIUM connects university engineering in Singapore and Japan with a demanding measurement problem: using radio signals to investigate the ionosphere. Its first satellite was released from the International Space Station on October 6, 2018. Kyutech describes telemetry containing a 10 MHz clock counter, one-pulse-per-second timing and temperature. Counting a clock is useful evidence, but the reference that defines each counting interval matters just as much as the count.
Build an original classroom experiment with nominal frequency f₀=10,000,000 cycles per second. A separate ideal reference defines equally spaced one-second boundaries. A cumulative counter C records oscillator cycles at those boundaries, with no resets, wraps or missed edges. For interval i, let nᵢ=Cᵢ₊₁−Cᵢ and yᵢ=nᵢ/(f₀τ)−1, where τ=1 second. The dimensionless yᵢ is fractional frequency error relative to that reference. These synthetic counters are not SPATIUM telemetry. An interval generated by the oscillator being tested would not independently validate its own frequency.
Read & understand
Compare successive interval means
Take counter readings 0, 10,000,002, 20,000,002, 30,000,004 and 40,000,004. Their interval counts alternate between 10,000,002 and 10,000,000, giving y=[2,0,2,0]×10⁻⁷. For M=4 contiguous interval means, use the non-overlapping two-sample estimator σᵧ(τ)=√{Σ(yᵢ₊₁−yᵢ)²/[2(M−1)]}. NIST explains this Allan-deviation estimator and distinguishes its averaging interval from the length of the complete record.
The three adjacent differences are −2,+2,−2, each in units of 10⁻⁷. Their squared sum is 12×10⁻¹⁴. Dividing by six and taking the square root gives σᵧ(1 s)=1.414×10⁻⁷. This is neither the average fractional error, which is 1×10⁻⁷, nor a guarantee that every reading lies within that deviation. It summarizes the changes between adjacent interval averages in this short, deliberately patterned record.
NASA astronaut Serena Auñón-Chancellor photographed preparation of the J-SSOD-10 deployment hardware on October 3, 2018. NASA identifies SPATIUM-I, RSP-00 and STARS-Me as its payloads. The complete frame shows the shared preparation setting; no individual spacecraft or clock board is identified within it.
Look closely
Can this preparation photograph establish the accuracy of SPATIUM’s clock?
See what to notice
It documents shared deployment preparation. Accuracy requires an independent timing reference, measurements and their uncertainty; those are not shown in the photograph.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Add a bias that the differences cannot reveal
Add the same b=3×10⁻⁷ to every interval. The new sequence is [5,3,5,3]×10⁻⁷. Each adjacent difference stays unchanged, so its Allan deviation stays 1.414×10⁻⁷ even though the mean becomes 4×10⁻⁷. This cancellation is algebraic: (yᵢ₊₁+b)−(yᵢ+b)=yᵢ₊₁−yᵢ. Better stability and smaller absolute frequency error are different claims.
For a clock whose displayed time is accumulated cycles divided by f₀, the added constant bias contributes bt to its time error. Over 100 seconds it adds +30 microseconds, assuming that bias persists. This is the additional error from b, not the total time error including the original sequence or an initial clock offset. A negative bias would make the clock fall behind. An imperfect reference contributes its own errors to the comparison and needs an uncertainty assessment before the result is attributed solely to the tested clock.
Stability can hide a constant bias
Original uniformly sampled fixture. The plotted connections aid reading; each point represents an interval mean. A real clock comparison includes reference and measurement uncertainty.
Open full-size diagram in a new tab: Stability can hide a constant biasCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Change the averaging time and preserve the record
Regroup the original four one-second values into two non-overlapping two-second means: [1,1]×10⁻⁷. Their difference is zero, so this tiny record gives σᵧ(2 s)=0. The alternating disturbance canceled inside each pair. That result does not turn the oscillator into a perfect clock; it describes one averaging time, one pattern and only one comparison. Longer observations and multiple averaging times reveal behavior that this fixture cannot.
A missing counter sample is not an ordinary one-second interval. Use actual timestamps and flag resets or discontinuities before forming differences. Do not silently interpolate a gap and present the invented values as measured noise. Keep the reference, interval length, estimator and record duration with the reported statistic. The SPATIUM hardware motivates the investigation; these calculations demonstrate how to interpret a measurement, without claiming the satellite achieved the classroom values or continuous operation today.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Kyutech: SPATIUM-I deployment and clock telemetryThe November 2018 report identifies the mission and recorded quantities; its contemporaneous plans are not current operational claims.
- Read: NIST SP 1065: frequency stability analysisSections 5.2.1–5.2.4 and 10 discuss Allan estimators, averaging and data handling. Counters and numerical results here are original exercises.