Lesson 2 of 4 · Convert fictional detector counts using explicit calibration assumptions before comparing bands.
Translate a measurement objective
8 minute lesson · 3 checks along the way
Your goal for this lessonConvert fictional detector counts using explicit calibration assumptions before comparing bands.
In this lesson 3 sections · 3 checks
Read & understand
Move from an optical aim to recorded numbers
A multiband imager separates incoming light into selected wavelength ranges and records a detector response for each. NCKU identifies multiband optical-imager development for E-VAC. The following original exercise explores the interpretation problem without assigning E-VAC any invented wavelengths, calibration constants, resolution or achieved science result.
Call the fictional channels A and B. A recorded count includes both the response to the input and any offset represented in the exercise. The channels can also have different gains. A larger raw count in one channel is therefore not, by itself, proof of a larger calibrated input. The conversion must use the appropriate channel’s parameters.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Apply a defined linear model
For this invented, linear, unsaturated detector, define calibrated signal S = (C − D) ÷ G. C is the recorded count, D is the dark offset in counts, and G is the gain in counts per arbitrary signal unit. Assume identical exposure duration, stable parameters and zero random error for this arithmetic exercise. These simplifying assumptions are not an E-VAC calibration model.
Channel A records 120 counts with a dark offset of 20 and a gain of 2, giving (120 − 20) ÷ 2 = 50 signal units. Channel B records 160 counts with an offset of 10 and a gain of 3, giving (160 − 10) ÷ 3 = 50. The unequal raw counts become equal calibrated values under the stated model. This comparison would be wrong if the parameters were exchanged.
Apply each channel’s own calibration
Fictional, linear, unsaturated model; fixed exposure; not E-VAC data.
Open full-size diagram in a new tab: Apply each channel’s own calibrationCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Retain what the conversion does not prove
In another fictional reading, A records 140 counts with the same offset and gain. Its calibrated value becomes 60 units, twenty percent above its earlier 50. That is a change within the defined model. It does not identify a physical cause: a changed input, calibration drift or altered observing conditions would require different supporting evidence in a real investigation.
If a fictional channel saturates at its maximum count, applying the same linear equation as though the response were unsaturated is unjustified. Likewise, different exposure times would need treatment before comparing readings. A useful measurement record retains channel identity, exposure, calibration version and quality flags alongside the values. A completed instrument is one prerequisite for observation, not a substitute for this interpretation work.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: NCKU: Space Optics LaboratoryLaboratory account identifies E-VAC multiband optical imager development; it does not establish an orbital measurement record.
- Read: NASA: product verificationGeneral guidance on requirements, test articles, configurations and methods; not a CKUTEX test report.
- Read: TASA: independent microsatellite programDistinguishes experimental CKUTEX and mission-oriented FORMOSAT-6, agency closure and university handoff.