Lesson 1 of 3 · Instrument response and polarization angle
Calibrate the modulation
12 minute lesson · 3 checks along the way
Your goal for this lessonRecover a polarization fraction and angle from a stated harmonic response while separating calibration, background and angle conventions.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
A second kind of information in the same photons
XPoSat launched on January 1, 2024 with two complementary instruments. Raman Research Institute developed POLIX with ISRO to study X-ray polarization; U R Rao Satellite Centre developed XSPECT for spectra and timing. Polarization describes the orientation pattern of the electric field. It can constrain emission geometry in ways that total brightness alone cannot, but the detector measures a statistical angular pattern rather than drawing a little arrow on each astronomical source.
POLIX uses scattering into surrounding counters. A reconstructed distribution can contain an instrumental angular pattern as well as a source signal. Our original fictional example assumes that event angles have already been converted into the electric-vector convention, with matched energy selection and stable calibration. It is a calculation about a declared response model, not a POLIX calibration release or an observation of a real source. The existing introductory survey remains useful for the mission overview; here we follow the inference step by step.
The DOS/ISRO XPoSat gallery records the PSLV-C58 launch on January 1, 2024. The small satellite carried its instruments to orbit; the bright exhaust is not an astronomical X-ray signal or polarization map. Resized and compressed from the official original. Photograph: Department of Space / Indian Space Research Organisation.
Look closely
Which scientific milestone needs evidence beyond this launch image?
See what to notice
First observations and calibrated polarization or spectral results need instrument data and analysis. Successful launch does not by itself complete those steps.
Read & understand
Define a harmonic and calibrate its response
Write the angular distribution as n(φ) = C[1 + a cos(2φ) + b sin(2φ)]. C is the mean level; a and b are normalized harmonic coefficients. The factor of two gives a 180-degree repetition: an electric-vector axis at zero degrees is equivalent to one at 180 degrees. With uniform angular acceptance, these harmonic coefficients are twice the corresponding mean cosine and sine. Do not mix them with a per-event Stokes convention that omits that factor.
Let the observed coefficient vector be m_obs, the calibrated instrumental offset be c, the modulation factor be μ and the source polarization fraction be p. For unpolarized background, define source fraction f = S/(S + B), where S and B are source and background counts. The toy response is m_obs = c + μfp(cos 2ψ, sin 2ψ). A fully polarized calibration beam with corrected amplitude 0.50 gives μ = 0.50. A different beam with p = 0.80 and amplitude 0.32 gives μ = 0.40, provided the calibration conditions match.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Correct components before taking a magnitude
For the first source fixture, m_obs = (0.14, 0.08) and c = (0.02, −0.01). Subtract component by component to obtain d = (0.12, 0.09). Its magnitude is sqrt(0.12² + 0.09²) = 0.15. With S = 9,000 and B = 3,000, f is 0.75. Using μ = 0.50 gives p = 0.15/(0.50 × 0.75) = 0.40, or forty percent. The offset, imperfect modulation and background dilution are three different operations.
The direction follows ψ = one half of atan2(d_b, d_a), reported modulo 180 degrees. Here atan2(0.09, 0.12) is about 36.87 degrees, so ψ is about 18.43 degrees. Using a one-argument arctangent can lose quadrant information. Subtracting the magnitudes of m_obs and c also gives the wrong correction in general: vectors must be subtracted before their length and direction are calculated. The worked values omit uncertainty solely to expose these operations.
Recover polarization from the measured pattern
Subtract the instrumental harmonic as a vector before correcting for modulation response and background dilution. All coefficients, calibration values and counts in this original model are fictional; its background is unpolarized and isotropic.
Open full-size diagram in a new tab: Recover polarization from the measured patternCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep the angle convention and evidence attached
For a raw scattering-angle distribution, maximum scattering can be perpendicular to the incoming electric-vector direction. Under the convention used in this course, subtract ninety degrees from the raw scattering maximum, then reduce modulo 180 degrees. A maximum at thirty degrees therefore corresponds to an electric-vector angle of 120 degrees. That conversion is different from halving the doubled angle returned by atan2. Our corrected vector fixture already uses the electric-vector convention, so it must not receive the ninety-degree adjustment again.
ISRO reported an early POLIX Crab pulse profile in February 2024. That is evidence of time-dependent counts; it is not, by itself, a calibrated polarization fraction with uncertainty. The October 2025 scientific-data release is another achieved milestone. For a particular physical inference, retain the response, event selection, background model and uncertainty. An offset or response that changes with energy may need a more detailed model than the scalar μ used here. A numerically recovered fraction outside zero to one signals a noisy or inadequate inference, not automatically impossible photons.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: PSLV-C58 / XPoSat MissionJanuary 2024 launch and complementary payload responsibilities. Objectives are separate from achieved calibrated science results.
- Read: POLIX onboard XPoSat commences its observationsFebruary 2024 report of early Crab counts and a pulse profile; it does not supply a calibrated polarization fraction with uncertainty.
- Read: XPoSat National Meet and scientific data releaseOctober 13, 2025 scientific-data and tools release. A release milestone does not validate every possible derived result.
- Read: ISRO Science Data Archive — XPoSatPublic mission archive and POLIX measurement architecture. No individual science dataset was analyzed for the fictional course exercises.
- Read: Analyzing the Data from X-ray Polarimeters with Stokes ParametersGeneral Stokes and counting-statistics methods, including angle conventions and finite background noise. Course observations, calibration and arithmetic fixtures are original.