Lesson 2 of 3 · Weighted polarization and coordinate frames
Combine Stokes vectors in one frame
12 minute lesson · 3 checks along the way
Your goal for this lessonAdd calibrated intensity and Stokes components, recover the pooled polarization, and distinguish a coordinate rotation from a physical change.
In this lesson 4 sections · 3 checks
Read & understand
A percentage is not an additive quantity
Two emission components can each be strongly polarized while their combined light is weakly polarized. Their orientations matter. To combine incoherent components on a common calibrated intensity scale, define Q = Ip cos(2ψ) and U = Ip sin(2ψ), where I is intensity, p is fractional linear polarization and ψ is its electric-vector angle. Add I, Q and U separately. Then recover p_total = sqrt(Q_total² + U_total²)/I_total and the half-angle of atan2(U_total, Q_total).
These are corrected physical Stokes quantities in a common band and reference frame. They are not arbitrary raw detector coefficients collected under different responses. A real combination across energy, pulse phase or observing epochs may require response weighting and background treatment. Our original fixtures assume those corrections have already been made, so their arithmetic isolates the effect of intensity and orientation. The quantities use arbitrary but shared intensity units; they are not XPoSat event totals.
Read & understand
Work through partial cancellation
Component A has I = 600, p = 0.50 and ψ = 0 degrees. It contributes Q = 300 and U = 0. Component B has I = 400 and p = 0.50 at ψ = 90 degrees. Its doubled angle is 180 degrees, so it contributes Q = −200 and U = 0. The combined intensity is 1,000 while Q is only 100. Thus the pooled polarization is 100/1,000 = 0.10, with angle zero degrees.
A weighted average of the two fifty-percent values would still give fifty percent and miss the cancellation. Likewise, averaging zero and ninety degrees would produce an angle that does not describe the summed vector. In an alternate fixture, I = 800, p = 0.25 at 45 degrees gives U = 200; I = 200, p = 0.50 at 135 degrees gives U = −100. Their total is again ten percent polarized, now at 45 degrees. The same percentage can accompany a different orientation.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Rotate the axes without rotating the source
Suppose the coordinate axes turn counterclockwise by χ while the physical beam stays fixed. Under this passive rotation, Q′ = Q cos(2χ) + U sin(2χ) and U′ = −Q sin(2χ) + U cos(2χ). For the first total, (Q, U) = (100, 0), and χ = 45 degrees. The transformed components are (0, −100). The reported angle in the new axes is −45 degrees, equivalent to 135 degrees modulo 180, while the polarization fraction remains ten percent.
This invariance gives a useful consistency check. Squaring and adding the transformed components cancels the mixed terms and preserves Q² + U². A changed component or angle label does not necessarily imply a changed source; the coordinate reference may have changed. Conversely, combining vectors expressed relative to different axes without transformation can invent cancellation or alignment. Record whether angles refer to detector axes, a sky reference or another explicitly defined frame.
Add Stokes vectors, not polarization angles
The polarization direction is defined modulo 180°, so Stokes components use twice the physical angle. Intensities and components add; polarization percentages and raw angles do not. This original example assumes corrected intensities in one band and frame.
Open full-size diagram in a new tab: Add Stokes vectors, not polarization anglesCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Respect wrapping and unresolved mixtures
Consider equal-intensity components each fifty percent polarized at five and 175 degrees. Those axes are close across the 180-degree boundary. Their doubled sine terms cancel, while the doubled cosine terms reinforce. The pooled fraction is 0.50 cos(10 degrees), about 0.4924, and its angle is zero degrees. An ordinary arithmetic average of the angle labels would give ninety degrees, nearly perpendicular to the correct result. Circular quantities need their declared vector representation.
If equal opposing Stokes vectors cancel exactly, Q = U = 0 and the polarization direction is undefined. A software atan2 function returning a number at zero does not create a physical direction. A low pooled fraction also does not prove that every region or phase is intrinsically unpolarized: unresolved polarized components can cancel. Separating energy bands or phases may reveal that structure, but consumes the counts available in each group. The next lesson evaluates that tradeoff before a compelling-looking pattern is treated as a detection.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Analyzing the Data from X-ray Polarimeters with Stokes ParametersGeneral Stokes and counting-statistics methods, including angle conventions and finite background noise. Course observations, calibration and arithmetic fixtures are original.
- Read: XSPECT on-board XPoSat: Calibration and First ResultsXSPECT team calibration and first results, June 2025. Pulse fraction concerns timing; it must not be confused with polarization fraction.
- Read: ISRO Science Data Archive — XPoSatPublic mission archive and POLIX measurement architecture. No individual science dataset was analyzed for the fictional course exercises.