Lesson 1 of 4 · Radiance, optical depth and mass
Define the dust measurement
18 minute lesson · 3 checks along the way
Your goal for this lessonDistinguish a calibrated band value from a monochromatic model and separate brightness, optical depth and dust mass.
In this lesson 3 sections · 3 checks
Read & understand
An observatory becomes an archive
Herschel launched on 14 May 2009. Its helium supply was exhausted on 29 April 2013, ending new scientific observations; that date is distinct from the later spacecraft shutdown. The preserved archive lets researchers revisit measurements after acquisition stops. The introductory survey explains why cool dust is visible at long wavelengths. Here we investigate the harder step: deciding what a measured spectrum actually tells us about temperature and material.
SPIRE photometer products quote values at reference wavelengths of 250, 350 and 500 micrometres. Real measurements cover wavelength bands, have angular responses and depend on calibration conventions. Historical NHSC documentation describes spectral-response and beam products as well as a reference spectrum used for quoted flux densities. Its old processing versions and correction factors should not be treated as current instructions. Our calculations below are deliberately monochromatic, with no real SPIRE calibration applied.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Name the quantity before fitting it
Use Iν for radiance per unit frequency, expressed in megajanskys per steradian, or MJy/sr. One MJy equals 10⁻²⁰ W m⁻² Hz⁻¹. Although a channel is labelled by wavelength λ, its frequency is ν=c/λ and the radiance convention remains per frequency. Bν(T)=2hν³/[c²(exp(hν/kT)−1)] is the Planck radiance. Temperature T is in kelvin; h, c and k are the Planck constant, speed of light and Boltzmann constant.
For the fictional cloud write Iν(λ)=τ500(500 µm/λ)^β Bν(T). The dimensionless τ500 is optical depth at 500 micrometres, while β sets the wavelength dependence over this limited interval. Assume one temperature, optically thin emission, identical spatial averaging, zero background and exact measurements. Substituting a per-wavelength Planck function Bλ without converting the density convention changes the ratio and answers a different question.
Herschel being raised in the ESTEC cleanroom for transfer to the Large Space Simulator, as identified in the existing ESA source record. Protective coverings, lifting equipment and people remain visible in the complete frame. This preparation photograph does not measure a dust temperature or validate a spectral fit. Credit: ESA/A. Le Floc'h.
Look closely
Does this preparation photograph establish the temperature of an astronomical dust cloud?
See what to notice
No. It documents spacecraft preparation. Dust temperatures require calibrated radiances, compatible spatial responses, a stated emission model and checks on its assumptions.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Separate amount from temperature
Take T=20 K, β=2 and τ500=0.001. The model gives approximately 606.449, 277.692 and 98.842 MJy/sr at 250, 350 and 500 micrometres. Doubling τ500 doubles all three intensities; it does not change their ratios. Increasing temperature changes both brightness and spectral shape. A single band cannot tell those changes apart without additional assumptions or information.
Optical depth is not dust mass in kilograms. A conversion needs a specified absorption opacity and a suitable geometry or surface-density interpretation. Even the emission equation is an approximation: an isolated isothermal slab has the factor 1−exp(−τ), which approaches τ when τ is small. At our largest base optical depth, 0.004 at 250 micrometres, the thin expression is about 0.2001% higher. That comparison checks this approximation only; it is not a calibration-accuracy claim.
More optical depth, same colour
Original optically thin example, not real SPIRE data. All bars share one scale. Optical depth is dimensionless; a mass conversion requires an opacity model and geometry.
Open full-size diagram in a new tab: More optical depth, same colourRead diagram data as a table
| Wavelength (µm) | Iν at τ500=0.001 (MJy/sr) | Iν at τ500=0.002 (MJy/sr) |
|---|---|---|
| 250 | 606.449 | 1212.898 |
| 350 | 277.692 | 555.385 |
| 500 | 98.842 | 197.685 |
Original optically thin example, not real SPIRE data. All bars share one scale. Optical depth is dimensionless; a mass conversion requires an opacity model and geometry.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: ESA: Herschel science observations endDated science endpoint; final spacecraft shutdown was later. Numerical spectra, optical depths, temperatures and spatial weights are original teaching values; real bandpass and beam calibration are outside the exercise.
- Read: NHSC: SPIRE photometer documentationHistorical calibration documentation; old processing versions and correction factors are not current instructions. Numerical spectra, optical depths, temperatures and spatial weights are original teaching values; real bandpass and beam calibration are outside the exercise.