Lesson 2 of 4 · Conditional two-band inference
Recover a conditional temperature
20 minute lesson · 3 checks along the way
Your goal for this lessonUse a two-band ratio to recover temperature and optical depth when the spectral index and emission model are fixed.
In this lesson 3 sections · 3 checks
Read & understand
Cancel one unknown
Let R=Iν(250)/Iν(500). If both channels describe the same single-temperature material with the same spatial averaging, τ500 cancels from the ratio. The frequency at 250 micrometres is twice the frequency at 500. Define x=hc/(500 µm kT); the denominator of the short-channel Planck function contains exp(2x)−1, whereas the long channel contains exp(x)−1.
The ratio is R=2^(β+3)[exp(x)−1]/[exp(2x)−1]. Factoring exp(2x)−1=[exp(x)−1][exp(x)+1] gives R=2^(β+3)/[exp(x)+1]. The factor 2³ comes from the frequency-cubed Planck numerator, and 2^β comes from the optical-depth law. This shortcut works because these two chosen wavelengths differ by exactly a factor of two.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Invert and reconstruct
Rearrange the expression to obtain T=[hc/(500 µm k)]/ln[2^(β+3)/R−1]. For the base spectrum, R≈6.13551. With β fixed at 2, the result is 20 K. Then use the long-channel amplitude to recover τ500=Iν(500)/Bν(500,T)=0.001. Reconstruct both input intensities as a check rather than trusting a temperature reported by itself.
If every intensity doubles while the ratio is unchanged, the recovered temperature remains 20 K and the inferred optical depth doubles to 0.002. The ratio carries shape information, while the amplitude supplies the conditional scale. Conversely, treating the absolute 250-channel intensity as a temperature would confuse a larger column with a hotter source. The calculation still presumes the same β and one emitting temperature.
Recover a conditional temperature
The ratio identity uses frequency-specific radiance and a factor-of-two wavelength pair. The finite positive-temperature ratio bound is16 for beta2. No uncertainty or real bandpass is modeled.
Open full-size diagram in a new tab: Recover a conditional temperatureRead diagram data as a table
| Step | Input or condition | Result |
|---|---|---|
| Ratio | 606.448953 / 98.842396 | 6.135514 |
| Temperature | β=2; x=hc/(500 µm kT) | 20 K |
| Optical depth | Iν(500)/Bν(500,T) | 0.001 |
| Allowed ratio | Finite positive T; β=2 | 0 < R < 16 |
The ratio identity uses frequency-specific radiance and a factor-of-two wavelength pair. The finite positive-temperature ratio bound is16 for beta2. No uncertainty or real bandpass is modeled.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Check whether a solution is possible
For finite positive temperature, x>0, so exp(x)+1>2. The allowed interval is therefore 0<R<2^(β+2). With β=2 the upper limit is 16. A ratio of exactly 16 approaches the infinite-temperature limit of this ideal model; it does not imply a finite temperature of 16 K. A larger ratio has no positive-temperature solution under these assumptions.
Approaching the upper limit also makes the inverse sensitive: a small change in ratio can produce a large temperature change. An algebraically valid answer is not automatically a precise measurement. Report the assumed β, channel convention and uncertainty treatment with a real result. We have deliberately omitted observational noise so that structural assumptions can be examined before statistical uncertainty is added.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source