Lesson 4 of 4 · Spatial response and temperature mixtures
Match the view, then test the mixture
21 minute lesson · 3 checks along the way
Your goal for this lessonDistinguish incompatible spatial averages from unresolved temperature mixtures and explain why a fitted colour temperature need not equal a column-weighted mean.
In this lesson 3 sections · 3 checks
Read & understand
Two cells, two ways to look
Consider equal-area cold and warm cells at 12 K and 30 K. Each has τ500=0.001 and β=2. First give every channel equal weights: half cold and half warm. Their mean intensities are approximately (917.662, 353.795, 114.622) MJy/sr in wavelength order. Because area and optical depth are equal, their column-weighted mean temperature under this common-opacity model is 21 K.
Now change only the short-channel spatial weights to 20% cold and 80% warm. Its intensity rises to 1417.414 MJy/sr, while the long-channel value stays 114.622. These are incompatible views of the two cells. The weights are invented spatial averages, not SPIRE beam profiles or smoothing kernels. Equal pixel coordinates alone would not establish equal angular response in a real multiband comparison.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
An impossible-looking colour temperature
Fit the mismatched 250 and 500 values with the single-temperature β=2 model. The inferred temperature is about 62.2418 K, hotter than either cell, with τ500≈0.000211966. No cell was heated by the observation. The high ratio arose because the short-channel measurement emphasized the warm component more strongly. A numerical fit cannot repair the mismatch if the input comparison does not represent the same weighting.
Restore equal weights at 250 micrometres, matching the other channels. The fitted temperature falls to about 26.2164 K and τ500 rises to about 0.000720202. Matching the response removed the particular spatial inconsistency. In real work this requires documented beam and map handling appropriate to the data, not applying these two-cell weights or assuming every instrument shares one response.
Match the spatial averages
Each stacked bar represents 100% of a spatial average; blue is the 12 K cell and gold the 30 K cell. Each cell has optical depth 0.001 and beta 2. The comparison uses the 250 and 500 micrometre channels. Spatial matching does not eliminate physical temperature mixtures.
Open full-size diagram in a new tab: Match the spatial averagesRead diagram data as a table
| Measurement | Cold-cell weight | Warm-cell weight |
|---|---|---|
| Unmatched 250 µm | 20% | 80% |
| 500 µm reference | 50% | 50% |
| Matched 250 µm | 50% | 50% |
Each stacked bar represents 100% of a spatial average; blue is the 12 K cell and gold the 30 K cell. Each cell has optical depth 0.001 and beta 2. The comparison uses the 250 and 500 micrometre channels. Spatial matching does not eliminate physical temperature mixtures.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
The mixture remains after matching
The matched fit is still not the 21 K column-weighted mean, and its inferred optical depth is below the true mean 0.001. Planck emission is nonlinear in temperature, so averaging radiances and then fitting one temperature need not equal averaging the physical temperatures first. The matched fit predicts about 358.675 MJy/sr at 350 micrometres, compared with 353.795 for the mixture: a residual of about −4.87965 MJy/sr.
This example is a counterexample, not a universal dust-mass correction. The amount and direction of bias depend on the temperature distribution, wavelengths, model and fitting procedure. A defensible report would call 26.2164 K a conditional colour temperature, state the common response and fixed β, show the unused-band residual and avoid converting τ into an unqualified mass. Better spatial matching and better physical modeling address different parts of the inference.
A matched view can still mix temperatures
Dots use a shared temperature axis in kelvin. Equal spatial weights remove the comparison mismatch but not nonlinear mixture effects. The unused 350 micrometre band residual is observed minus predicted in MJy/sr; no universal mass correction follows.
Open full-size diagram in a new tab: A matched view can still mix temperaturesRead diagram data as a table
| Quantity | Value | Meaning |
|---|---|---|
| Cold cell | 12 K | Physical input |
| Warm cell | 30 K | Physical input |
| Column-weighted mean | 21 K | Equal optical depths and common opacity |
| Colour temperature | 26.2164 K | Conditional single-temperature fit |
| Mean optical depth | 0.001 | Dimensionless |
| Fitted optical depth | 0.000720202 | Dimensionless |
| 350 observed / predicted | 353.795 / 358.675 MJy/sr | Residual −4.87965 MJy/sr |
Dots use a shared temperature axis in kelvin. Equal spatial weights remove the comparison mismatch but not nonlinear mixture effects. The unused 350 micrometre band residual is observed minus predicted in MJy/sr; no universal mass correction follows.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: NHSC: SPIRE photometer documentationHistorical calibration documentation; old processing versions and correction factors are not current instructions. Numerical spectra, optical depths, temperatures and spatial weights are original teaching values; real bandpass and beam calibration are outside the exercise.
- Read: Kelly and colleagues: dust spectral fittingAbstract reviewed for temperature–spectral-index degeneracy; this course does not reproduce the authors’ statistical method. Numerical spectra, optical depths, temperatures and spatial weights are original teaching values; real bandpass and beam calibration are outside the exercise.