Lesson 3 of 3 · Multi-sensor magnetic interference rejection
Separate the Moon’s field from the spacecraft
19 minute lesson · 3 checks along the way
Your goal for this lessonSeparate a common external magnetic component from differently coupled spacecraft interference and assess the noise cost and model limits.
In this lesson 4 sections · 3 checks
Read & understand
Measure the instrument’s surroundings as well as the Moon
Danuri’s KMAG uses three fluxgate sensors to help separate the external magnetic environment from the spacecraft’s own magnetic contributions. Published processing uses multi-sensor information and calibration; the spacecraft is not assumed magnetically invisible. Removing its interference also does not prove that the remaining field comes solely from lunar material. The surrounding plasma environment and other external sources can contribute. This lesson develops an original scalar model that explains one separation principle without reproducing the full vector or principal-component pipeline.
Write each calibrated sensor reading as yi = B + aiD. B is one external component, assumed common over the sensor separation; D is one spacecraft-disturbance amplitude; and ai is a known dimensionless coupling. Assume calibrated zero offsets, stable couplings, no external gradient across the boom and no additional disturbance sources. Invent a = [1,0.5,0.25] and readings y = [18,14,12] nT. The coupling values are not literal sensor distances or an asserted inverse-cube law. Their distinct values, rather than distance labels alone, make the two components separable.
Read & understand
Solve with two sensors and test with the third
Subtract the second reading from the first: 18 − 14 = (1 − 0.5)D, giving D = 8 nT. Then B = 14 − 0.5 × 8 = 10 nT. Equivalently B = 2y2 − y1. Both original equations are satisfied: 10 + 8 = 18 and 10 + 4 = 14. The third sensor, reserved from this two-sensor fit, should read 10 + 0.25 × 8 = 12 nT. Its agreement provides a check on the assumed common field and coupling pattern.
If that third reading were 13 nT, its residual would be +1 nT. The residual would not, by itself, establish a lunar anomaly or tell which sensor is wrong. It could indicate a calibrated-offset error, another disturbance source, an external gradient, noise or changing coupling. Conversely, a zero residual does not prove the model uniquely correct; some unmodeled effects can imitate its pattern. Reserving an observation for prediction is useful precisely because it tests more than the algebra used to obtain the fitted parameters.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Calculate the noise cost of subtraction
Suppose the first two sensors have independent zero-mean random errors, each with standard deviation 0.2 nT, while the couplings are exact. For B = −y1 + 2y2, the variance is (−1)² × 0.2² + 2² × 0.2² = 0.20 nT². The standard deviation is √0.20 ≈ 0.447214 nT. The disturbance cancels algebraically, but the independent sensor noise does not. Adding the two standard deviations linearly would answer a different question from the independent random-error propagation specified here.
Bring the couplings closer: a1 = 1 and a2 = 0.9. The common-field estimator becomes B = −9y1 + 10y2. With the same independent 0.2 nT errors, its standard deviation is 0.2√181 ≈ 2.690725 nT. Disturbance separation has become much noisier because the two sensors respond almost alike. If their couplings are exactly equal, these readings cannot separate B and D at all. Better precision can help a poorly conditioned estimate, but it cannot create the missing distinction in an exactly degenerate model.
Separate a common field from interference
Original calibrated-coupling model. Third-sensor agreement tests consistency but cannot rule out a shared offset or establish a uniquely lunar source. The complete KMAG pipeline is more complex.
Open full-size diagram in a new tab: Separate a common field from interferenceCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Carry calibration assumptions into the interpretation
Try alternate known couplings [0.8,0.2,0.1] and readings [10.8,7.2,6.6] nT. The first pair gives D = (10.8 − 7.2)/(0.8 − 0.2) = 6 nT and B = 6 nT. The third prediction is 6 + 0.1 × 6 = 6.6 nT. Here B = −y1/3 + 4y2/3. With independent 0.3 nT errors on the first two sensors, its standard deviation is 0.3√(17/9) ≈ 0.412311 nT. The same subtraction method has a different noise cost because its calibrated response pattern differs.
Shared errors do not follow the independent-noise calculation: covariance terms can either increase or decrease the estimator’s variance. Uncertain offsets and couplings also need their own error treatment. KMAG’s published work discusses spacecraft-noise removal, while a separate 2026 study addresses temperature-associated long-term calibration. Neither is replaced by assuming that the cleanest-looking time series is the most accurate. Retain the calibration model and validation residuals with the external-field estimate, and use spatial, temporal and independent observations before attributing a remaining signal to a lunar source. An unknown offset c shared by every sensor is inseparable from B: the readings determine B + c, even when the third sensor agrees.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: KMAG instrument and initial processingInstrument identity and three-sensor configuration. The scalar coupling values in this lesson are invented.
- Read: Correction of spacecraft magnetic field noiseSections 2–3 and 5 develop multi-sensor correction and its limits for a dated cruise observation; this lesson does not reproduce the full PCA pipeline.
- Read: In-orbit temperature calibration of KMAG2026 study of longer-term calibration and residual checks. A temperature-associated trend is not proof that every remaining effect has one cause.