Lesson 1 of 3 · Time-delay integration and image motion
Keep charge synchronized with a moving scene
18 minute lesson · 3 checks along the way
Your goal for this lessonCompare charge-domain integration with separate readouts and calculate how timing mismatch shifts a moving scene across detector stages.
In this lesson 4 sections · 3 checks
Read & understand
Follow the scene while collecting faint light
Danuri is the flown orbiter case study within South Korea’s broader lunar-exploration program. Its NASA-provided ShadowCam images terrain illuminated by reflected light inside lunar shadows. The camera’s time-delay integration, or TDI, moves collected charge through detector stages in step with the image. This increases the signal from a moving scene without asking that scene to remain fixed on one pixel. It also makes timing part of image quality. A bright or sharp feature in such an image is not, by itself, a unique identification of ice.
Build an original eight-stage detector, separate from ShadowCam’s 32 illuminated TDI stages. A projected pixel spans 2 m on the surface, and the image moves at 1,600 m/s in that projected coordinate. The matching line time is 2/1,600 = 0.00125 s, or 1.25 ms. Assume constant scene brightness and speed, perfect charge transfer, no saturation and equal dwell times. An ideal charge packet receives eight full dwells, so its integration time is 10 ms. The centers of the first and last dwell are only seven line intervals apart: 8.75 ms.
Read & understand
Count charge and independent readouts separately
Let the packet collect a mean of 25 photoelectrons per stage and let the final electronic read have a standard deviation of 5 electrons. Eight stages give mean signal S = 8 × 25 = 200 electrons. Independent Poisson arrivals have total shot-noise variance 200; one final read adds variance 5² = 25. The total standard deviation is √225 = 15 electrons and SNR = 200/15 = 13.3333. Variances add here because the specified random terms are independent, not because all possible detector errors obey that rule.
Compare eight separately read exposures of the same scene with the same total expected photons and perfect registration before summing. Their shot variance still totals 200, but eight independent read noises contribute 8 × 25 = 200. Total standard deviation becomes √400 = 20 and SNR = 10. The improvement comes from avoiding repeated read noise while accumulating charge; it is not eight times the SNR and does not create additional photons. If read noise were negligible, both methods would approach the same shot-noise limit for the stated equal total signal.
Falcon 9 launches Danuri from Cape Canaveral in August 2022. The lunar orbiter is enclosed within the launch vehicle’s fairing; its instruments and later lunar observations are not visible in this launch photograph. The appearance of U.S. Department of War (DoW) visual information does not imply or constitute DoW endorsement.
Look closely
Which later milestone needs evidence beyond the launch image?
See what to notice
Lunar orbit insertion and returned instrument measurements need their own mission records.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Measure drift across stage centers
Now suppose the image advances 1.01 pixels during each commanded one-pixel charge transfer. The signed mismatch is +0.01 pixel per interval. Between eight stage centers there are seven intervals, so first-to-last mismatch is +0.07 pixel. Counting eight intervals would confuse the total number of integration dwells with the separation between their centers. This calculation describes the spread of sampled positions, not the complete point-spread function: each dwell also integrates over a finite duration and pixel area, and the optics have their own response.
A high signal-to-noise ratio cannot correct an image that accumulated light from misaligned positions. The ShadowCam instrument paper explains how terrain distance changes the appropriate line timing across a scene and how segmentation can trade coverage for less smear. In our ideal model, reducing the timing mismatch aligns stage centers without changing the noise bookkeeping. In actual operation, illumination, orbit knowledge, topography, charge-transfer behavior and saturation all matter. Choose an exposure plan using both signal quality and spatial sharpness, rather than treating one as a substitute for the other.
Follow the image; read the charge once
Original TDI example. Eight integration dwells and seven center-to-center intervals are different counts. Ideal random-noise performance does not capture saturation, artifacts or the complete image blur.
Open full-size diagram in a new tab: Follow the image; read the charge onceCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Transfer the method to a second detector
For an alternate invented detector, use six stages, a projected pixel of 3 m and image speed 1,500 m/s. The line time is 2 ms, total integration is 12 ms, and the first-to-last center interval is 10 ms. At 16 photoelectrons per stage the mean signal is 96. With 4-electron read noise, one final read gives SNR = 96/√(96 + 16) ≈ 9.0711; six separate reads give 96/√(96 + 6 × 16) ≈ 6.9282. A +2% advance mismatch accumulates +0.10 pixel across five intervals.
These values are original teaching inputs, not ShadowCam performance specifications. The calibration paper examines photon-transfer behavior as well as signal-dependent and stray-light artifacts that our ideal calculation omits. Report whether noise is a standard deviation or variance, whether charge is read once or repeatedly, and whether a quoted time is an integration duration or a center-to-center span. Those distinctions keep a correct numerical result attached to the detector process it describes. More stages can improve faint-light measurements while increasing the consequences of mistiming and saturation. At fixed photon rate, doubling synchronized image speed halves each dwell’s photons. Increasing stages at fixed dwell can instead exceed charge capacity, where the unsaturated linear SNR formula no longer applies.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: ShadowCam instrument and investigation overviewSections 4–5 describe exposed TDI stages, timing and terrain-dependent smear. The eight- and six-stage examples are original simplified detectors.
- Read: Calibration of ShadowCamSection 5.1 gives the shot/read-noise variance relation; artifact and saturation discussions explain why ideal SNR alone is incomplete.