Lesson 2 of 3 · Nonlocal contamination and calibration order
Undo smear in the right calibration order
19 minute lesson · 3 checks along the way
Your goal for this lessonInvert a response-and-mixing model in the correct order and bound an unknown signal when a contributing neighbor is not measured.
In this lesson 4 sections · 3 checks
Read & understand
Write the forward process before undoing it
Danuri’s PolCam measures lunar polarization, but a useful polarimetric product depends on correcting detector artifacts first. Its 2026 calibration manuscript separates dark correction, charge-transfer smear and response normalization. It also describes reconstruction of unread rows and remaining limits on absolute calibration. Artifact correction and absolute radiance or polarization calibration are different achievements. The example below studies why processing order matters; it is a static two-element model, not a reconstruction of PolCam’s frame-coupled method.
Let the true two-element scene be x = [50,40] in consistent arbitrary signal units. A known pre-mixing response G = diag(2,1) gives z = Gx = [100,40]. G represents response before the mixing, not an electronic amplifier placed afterward. Let A = [[1,0.2],[0.1,1]] mix those signals, and let d be a known additive offset. The recorded vector is y = AGx + d. After subtracting d, the observed vector u = y − d is [108,50]. Keep this forward order explicit: response, then mixing, then offset.
Read & understand
Undo the operations in reverse order
The two offset-corrected equations are u1 = z1 + 0.2z2 and u2 = 0.1z1 + z2. Their determinant is 1 − 0.02 = 0.98, so the inverse exists. Solve z1 = (u1 − 0.2u2)/0.98 = (108 − 10)/0.98 = 100 and z2 = (u2 − 0.1u1)/0.98 = (50 − 10.8)/0.98 = 40. Only then undo G: x1 = z1/2 = 50 and x2 = z2 = 40. Forward substitution returns [108,50], checking the inverse against the stated model.
If response normalization is applied first, G⁻¹u = [54,50]. Feeding that vector into the same A⁻¹ gives approximately [44.897959,45.510204], not the true scene. In operator notation, the correct inverse is G⁻¹A⁻¹, acting from right to left; swapping it to A⁻¹G⁻¹ changes the result because the operators do not commute. Scaling one channel changes how its contribution should enter a cross-channel subtraction. This failure is systematic: collecting more identical exposures does not make the wrong order become correct. Equal scalar response, such as G = 3I, is a special commuting case; additive offsets still require consistent treatment.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Bound the missing contributor instead of inventing it
Suppose only u1 = 108 is recorded and the response-weighted neighbor z2 is unknown. Independent evidence bounds z2 between 0 and 80. From z1 = 108 − 0.2z2, infer z1 = 92–108, and therefore x1 = z1/2 = 46–54. The interval reverses endpoint order because increasing the contaminating neighbor lowers the required local signal. It is a deterministic bound conditional on exact coefficients and the stated neighbor range, not a standard uncertainty or a probability interval.
Setting the missing neighbor to zero would select the upper endpoint, x1 = 54, without evidence that zero is appropriate. Treating a missing readout as a measured zero silently changes the problem. If both channels are recorded but the mixing determinant is nearly zero, an inverse can still amplify small measurement errors strongly. Check which measurements are available, whether the coefficients are calibrated, and whether the solution is stable. A mathematically invertible matrix does not guarantee a practically useful estimate when the inputs are uncertain.
Undo the chain in reverse order
Original linear calibration chain. G describes response before mixing. Real PolCam processing includes frame coupling and reconstruction of unread rows; cleaner images do not alone establish absolute calibration.
Open full-size diagram in a new tab: Undo the chain in reverse orderCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Distinguish a corrected image from an absolute measurement
For another invented chain, use x = [30,20], G = diag(1,3), A = [[1,0.25],[0.2,1]] and d = [4,6]. The raw vector is [49,72]; subtracting d leaves [45,66]. The determinant is 0.95. Unmixing gives z = [30,60], then response normalization returns x = [30,20]. Reversing those inverse operations instead gives approximately [41.578947,13.684211]. If only u1 = 45 is available and z2 lies in 40–80, then x1 = z1 = 45 − 0.25z2 lies in 25–35.
PolCam’s actual correction must contend with signals from rows not recorded in each observation, so reconstructed contributions and residual artifacts remain part of the interpretation. The September 2026 manuscript also keeps relative-response correction distinct from absolute radiometric and polarimetric calibration. Our matrices demonstrate a transferable rule: define the physical or stipulated forward sequence, reverse it consistently, and expose dependencies on unobserved inputs. A cleaner-looking image is evidence of improved processing only within the tested conditions; it does not alone establish an absolute polarization scale or a unique surface composition.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.