Lesson 3 of 4 · Storage, reserve and unmet demand
Respect storage and reserve
18 minute lesson · 3 checks along the way
Your goal for this lessonTrack storage, discarded surplus and unmet demand without confusing final charge with successful operation.
In this lesson 3 sections · 3 checks
Read & understand
A full store cannot keep every surplus
Start the sun-first schedule with 2 watt-hours. The first interval has a net surplus of 9 watts. Filling the remaining 3 watt-hours takes twenty minutes, so storage reaches its 5-watt-hour limit at minute 20. During the next thirty minutes, another 4.5 watt-hours cannot be retained in this model.
During the radio interval, generation still exceeds demand by 3 watts. Storage remains full and another 0.5 watt-hour is discarded. Darkness then consumes 3 × (30/60) = 1.5 watt-hours. The window ends at 3.5 watt-hours, with 5 discarded, no unmet demand and a minimum stored amount of 2. Nothing in this calculation claims that the discarded energy could have been saved without changing the storage model.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Later sunlight cannot serve an earlier task
Now start with darkness. The first ten minutes request 1.5 watt-hours, reducing storage from 2 to 0.5. Storage crosses the 1-watt-hour reserve after 6⅔ minutes and is below it thereafter. Equality with the reserve is not a breach; falling below it is. The reserve is a monitoring threshold here, not an automatic shutdown rule.
The next twenty minutes request 1 watt-hour. Only 0.5 remains, so storage empties at minute 20 and another 0.5 watt-hour of requested energy goes unserved before sunlight begins at minute 30. We never record negative stored energy. The later sixty minutes refill storage to 5 and discard 4 watt-hours. Ending full therefore hides both an earlier reserve breach and unmet demand.
Stored energy through both schedules
Original fictional model: initial storage 2 Wh, capacity 5 Wh, unity efficiency. Lines join exact change points. The reserve is a monitored threshold, not a shutdown rule; unmet demand is recorded separately.
Open full-size diagram in a new tab: Stored energy through both schedulesRead diagram data as a table
| Schedule | Time (min) | Stored energy (Wh) |
|---|---|---|
| Sun-first | 0 | 2 |
| Sun-first | 20 | 5 |
| Sun-first | 60 | 5 |
| Sun-first | 90 | 3.5 |
| Dark-first | 0 | 2 |
| Dark-first | 10 | 0.5 |
| Dark-first | 20 | 0 |
| Dark-first | 30 | 0 |
| Dark-first | 63⅓ | 5 |
| Dark-first | 90 | 5 |
Original fictional model: initial storage 2 Wh, capacity 5 Wh, unity efficiency. Lines join exact change points. The reserve is a monitored threshold, not a shutdown rule; unmet demand is recorded separately.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Keep the accounting honest
Energy conservation provides a separate check: initial storage plus generation equals final storage plus served demand plus discarded energy. For sun-first, 2 + 12 = 3.5 + 5.5 + 5. For dark-first, 2 + 12 = 5 + 5 + 4. Its served demand is 5 rather than the requested 5.5 watt-hours. Counting all requested energy as served would make the ledger inconsistent.
Unserved watt-hours quantify a shortage in this simplified model, not its exact operational consequence. Real equipment might switch off, reboot, reduce its load or require recovery time. We have modeled none of those responses. Once a plan needs more energy than is available, the ledger diagnoses a problem; it does not predict which messages would actually be transmitted afterward.
Energy conservation with unmet demand
All table energy values are Wh. Requested energy is 5.5 Wh in each fictional schedule. Unmet demand is not energy delivered and is excluded from the conservation sum.
Open full-size diagram in a new tab: Energy conservation with unmet demandRead diagram data as a table
| Schedule | Initial | Generated | Final | Served | Discarded | Unmet |
|---|---|---|---|---|---|---|
| Sun-first | 2 | 12 | 3.5 | 5.5 | 5 | 0 |
| Dark-first | 2 | 12 | 5 | 5 | 4 | 0.5 |
All table energy values are Wh. Requested energy is 5.5 Wh in each fictional schedule. Unmet demand is not energy delivered and is excluded from the conservation sum.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.