Lesson 2 of 3 · Time, illumination and apparent hysteresis
Reconstruct a changing-light sweep
24 minute lesson · 3 checks along the way
Your goal for this lessonReconstruct a sampled current–voltage curve under an explicit illumination model, and distinguish a sweep discrepancy from evidence of an intrinsic device change.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
A curve is assembled over time
An I–V sweep steps through voltages and records a current at each step. Its plotted points are not necessarily simultaneous observations of one unchanging cell. If sunlight, temperature or device state changes while the sweep runs, the resulting shape mixes those changes with the voltage response. Measuring back toward the starting voltage can produce another curve even when the cell has no intrinsic memory.
Reb and colleagues’ separate OHSCIS sounding-rocket experiment recorded forward and reverse sweeps and related them to changing illumination. Their analysis discusses window contamination, geometric shading and correlated temperature and illumination. That work is useful measurement context, not Zeus-1 telemetry. Its Figures 1–3 show why the timing and optical path of a reference measurement matter. We will construct a deliberately simple example in which the cause of the mismatch is known.
Read & understand
Keep each sample paired with its illumination
Hold temperature and device state fixed. At four voltages, 0.5, 1.0, 1.5 and 2.0 V, suppose reference-condition currents are 25, 20, 15 and 10 mA. Define a dimensionless illumination factor g, with g=1 at the reference condition. For this exercise alone, assume current at every listed voltage scales exactly with g while the voltage locations remain fixed. This is not a general perovskite model: real voltage response, spectrum, temperature and partial shading can invalidate that scaling.
During an increasing-voltage sweep, let g be 1.0, 0.8, 0.6 and 0.4 at those four respective samples. The recorded currents become 25, 16, 9 and 4 mA. Their powers are 12.5, 16, 13.5 and 8 mW. The largest sampled power is 16 mW at 1.0 V, but those samples were taken under different illumination. Calling it the cell’s maximum at one fixed illumination would combine incompatible conditions.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Compare corresponding voltages, not array positions
Now sweep downward, measuring 2.0, 1.5, 1.0 and 0.5 V in that time order. Let g again fall through 1.0, 0.8, 0.6 and 0.4. In ascending voltage order for comparison, the reverse sweep has currents 10, 12, 12 and 10 mA. At 1.0 V the first sweep recorded 16 mA while the reverse recorded 12 mA. At 2.0 V the reverse recorded 10 mA instead of four. Pairing the first element of each time-ordered list would incorrectly compare different voltages.
Divide every recorded current by its own simultaneous g. Both sweeps recover 25, 20, 15 and 10 mA in ascending voltage order. The corresponding normalized sampled powers are 12.5, 20, 22.5 and 20 mW, with the highest at 1.5 V. Thus all of this example’s discrepancy comes from changing illumination. The exercise does not prove that real perovskite cells lack hysteresis; it demonstrates why a forward/reverse mismatch alone cannot identify an intrinsic memory effect.
Match the voltage and illumination before comparing sweep currents
Original proportional-current model at fixed temperature and device state. Reverse samples are reordered by voltage, not left in acquisition order. These are not Zeus-1 measurements or a universal perovskite correction.
Open full-size diagram in a new tab: Match the voltage and illumination before comparing sweep currentsCheck 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Check the reference before trusting the correction
If a current is 20 mA at true g=1 but the reference reports 1.10, the computed normalized current is 20/1.10≈18.18 mA. That is about 9.09 percent low. A biased reference can manufacture an apparent loss after correction. A time-shifted reference can also assign the wrong illumination to a sample. Matching clocks is necessary, and the measurement interval, settling time and exposure averaging must also be compatible.
A nearby reference sensor need not see the same spectrum, angle, mask shadow or contamination as the test cell. Record those differences and assess the uncertainty of the correction. A stronger comparison repeats measurements under stable conditions, checks both scan directions and defined settling times, and uses references with a documented response. A residual discrepancy is a reason to investigate the model and device dynamics. It is not by itself proof of permanent degradation. Zeus-1’s endpoint measurements and any later campaign should be interpreted according to their actual measurement design, not the full sweeps imagined here.
Check 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Reb et al.: space and postflight solar-cell characterizationComplete Sections 1–3 and Figures 1–3 reviewed. This is a separate sounding-rocket experiment; its actual analysis is more detailed than the proportional-current exercise.
- Read: DLR: author-institution copy of the measurement paperOpen institutional record for the same 2023 paper, including its published PDF.
- Read: CEA: scope of the Zeus-1 measurementsThe documented endpoint devices are not replaced here with an invented Zeus-1 full-sweep data set.