Lesson 3 of 3 · Conditional effects, interactions and independent evidence
Separate stresses and replicates
24 minute lesson · 3 checks along the way
Your goal for this lessonCalculate conditional stress effects and a difference-of-differences interaction, then distinguish independent devices, repeated readings and uncertainty bounds.
In this lesson 4 sections · 3 checks
Using archive links & definitions
Follow a linked name to explore its archive card. “Back to your lesson” brings you to the same part of the reading.
Read & understand
Define the response and cross the factors
A ground comparison is useful only when its differences are interpretable. For an original aging study, choose two temperature levels, low and high, and two electrical holding conditions, A and B. Keep aging duration and other conditions the same. After exposure, measure each device under the same reference illumination and temperature, and express its retained power as a percentage of its own initial value. This separates the aging exposure from the subsequent measurement condition.
Use all four combinations: low/A, high/A, low/B and high/B. This is a two-by-two factorial design. Imagine group means of 100, 90, 95 and 70 percent, respectively. These are invented teaching values, not Zeus-1 results. Biaou and colleagues provide a real, separate perovskite study involving temperature, electrical load and aging time. Their condition labeled MPP used a fixed 1,000-ohm resistor, which is not continuous tracking of a changing maximum-power point. An experimental label needs an operational definition.
Read & understand
An effect can depend on the other condition
Under A, increasing temperature changes retention from 100 to 90 percent: a decrease of ten percentage points. Under B, the same temperature change moves 95 to 70 percent: a decrease of twenty-five points. The equal-weight average temperature effect is (−10−25)/2=−17.5 points. Reporting only that average hides the stronger change under B.
Define the interaction contrast here as the temperature effect under B minus the temperature effect under A: (70−95)−(90−100)=−15 percentage points. Equivalently, an additive prediction starts at 100, subtracts the ten-point temperature change under A and the five-point A-to-B change at low temperature, and predicts 85. The observed joint-condition mean of 70 is fifteen points below that prediction. We use the term contrast explicitly; factorial-effect and regression-coefficient conventions can assign different numerical scales to the same pattern.
Check 1 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Replicate devices, not just readouts
Suppose three independently prepared devices are assigned to each combination, for twelve devices total. Reading every device ten times produces 120 readings, but it does not create 120 independent device replicates. Readings from one device share its fabrication history and exposure. They can characterize readout variation or a time course while leaving uncertainty about device-to-device variation unresolved.
Randomly allocate suitable devices to conditions and account for fabrication batches. If every high-temperature device comes from one batch and every low-temperature device from another, temperature is mixed with batch. Likewise, one chamber per temperature can mix chamber behavior with the temperature comparison. Four group means alone fit a four-parameter model exactly, leaving no residual degrees of freedom for estimating noise. NIST’s factorial examples make that distinction clear. A perfect fit to those four means is not evidence that the interaction is statistically reliable or identifies a physical defect mechanism.
Check 2 of 3
10 pointsUse the reading above. You can try again without losing points.
Read & understand
Carry uncertainty into the claim
Assume, solely for a bounded-error exercise, that each of the four group means is within one percentage point of its stated value. The contrast combines four means with coefficients +1, −1, −1 and +1. In the worst case, their errors add in magnitude to four points. The interaction contrast is therefore bounded from −19 to −11 points. This is an assumed error bound, not a confidence interval or a probability statement. Statistical uncertainty requires a justified model and appropriate independent replication.
Even a well-controlled ground factorial study covers only its tested material, stress levels, duration and environment. A ground-versus-flight difference may also include transport, handling, vacuum, radiation, temperature history or measurement differences. Retain matched references, record exposures and distinguish hypotheses about causes from demonstrated effects. CEA’s planned Zeus-1 ground comparison motivates these questions; neither the original numerical exercise nor another laboratory study establishes that mission’s degradation mechanism.
A factorial contrast separates conditional changes from an additive prediction
Original factorial example. The interaction is explicitly a difference-of-differences contrast. Its assumed worst-case error interval is not a confidence interval, and the numbers do not describe Zeus-1.
Open full-size diagram in a new tab: A factorial contrast separates conditional changes from an additive predictionCheck 3 of 3
10 pointsUse the reading above. You can try again without losing points.
Put it together
Your lesson progress
Each check connects to a part of the story. Complete all 3 to earn your 25-point lesson bonus.
Explore further · Optional
Go to the source
Explore the evidence behind this lesson. These optional readings and videos open in a new tab.
- Read: Biaou et al.: defects and multifactorial perovskite agingComplete seven-page paper, Figures 1–6 and Table 1 reviewed. Its unreplicated design, missing cells and fixed-resistor load limit what is transferred to this original exercise.
- Read: EPFL: author-institution paper copyPublished paper: Tracking deep-level defects in degrading perovskite solar cells with a multifactorial approach.
- Read: NIST: two-level full factorial designsComplete page text and tables reviewed, including treatment combinations, replication and design order.
- Read: NIST: the two-by-two factorial modelComplete text and equations reviewed. Effect and coefficient conventions differ; four observations fit the four model parameters exactly.